Welcome to the Alteryx Knowledge Base

DCM connection with Snowflake Key-Pair auth method fails in Server 2025.1 job run.
user

Created/Edited - 12/24/2025 by Daniel Barber | Alteryx

Summary
DCM connection with Snowflake Key-Pair auth method fails in Server 2025.1 job run.
Description

DCM connections with Snowflake Key-Pair authentication fail in Alteryx Server 2025.1 with error "Selected Connection is malformed: Subobject was not loaded. Check the Connection or use a new one to use the tool" when running the job.

Issue

When running workflows that use a Snowflake DCM connection with Key-Pair authentication method via the Gallery in Alteryx Server 2025.1, users encounter the error:

Selected Connection is malformed: Subobject was not loaded. Check the Connection or use a new one to use the tool.

 

 

These workflows run successfully when executed locally on the Designer, but fail when triggered through Server UI.

Environment
  • Server 2025.1 using DCM connection with Snowflake Key-Pair auth method
Cause

Defect (GCSE-3560) has been submitted for further investigation.

Resolution

This has been reported as defect (GCSE-3560). As a workaround, you can modify the Key File password in the DCM credential by adding a single space character (e.g., at the end or beginning of the password field). This adjustment allows the Server UI to correctly process the Key-Pair authentication and enables workflows to run successfully from the Gallery.

 

Steps to apply the workaround:

1. Open the Data Connection Manager in Alteryx Server.

2. Locate the Snowflake connection using Key-Pair authentication.

3. Edit the credential and add a space character in the Key File password field.

4. Save the changes, synchronize the DCM connection to Gallery, and re-run the workflow from the Gallery.

Additional Information

If you continue to experience issues after applying this workaround, please contact Alteryx Support for further assistance.

Was this article helpful?