Welcome to the Alteryx Knowledge Base
Created/Edited -
When attempting to generate a binary (.bin) response file for offline license activation, users may encounter a "Requestor ID is invalid" error.
This error can occur when the request (.req) file is submitted to an incorrect licensing portal or when an activation response file is no longer valid.
When generating a response file for offline license activation, the following error message appears:
A response has been generated, but it reports the following status: The Requestor ID is invalid. Download the Capability Response.
The error prevents users from successfully completing the offline license activation process.
- Alteryx One
- Offline license activation
Before troubleshooting, ensure that:
-
You have access to the Alteryx Downloads and Licenses (D&L) Portal.
-
You have the request (.req) file associated with the activation attempt.
-
You can identify which licensing portal was used to generate or process the request.
The error can occur for several reasons:
-
Incorrect licensing portal: The .req file was uploaded to the wrong licensing portal, such as the Alteryx Analytics Cloud (AAC) portal instead of the legacy Downloads and Licenses portal.
-
Expired activation response: More than 72 hours have elapsed before attempting to use a key-based .bin activation response file.
-
Invalid request or licensing information: The .req file or associated licensing information may be invalid or incompatible with the selected activation workflow.
Follow these steps to resolve the error:
-
Access the correct licensing portal.
-
Navigate to the Alteryx Downloads and Licenses Portal.
-
Follow the portal instructions to create or access the required Community and Flexera accounts.
-
-
Verify the licensing workflow.
-
Confirm that you are using the correct portal for your license activation method.
-
If you are using a legacy Flexera .req file, ensure you follow the corresponding legacy licensing workflow.
-
Do not upload a legacy Flexera .req file to the Alteryx Analytics Cloud licensing portal.
-
-
Check the activation response file's validity.
-
If you are using a key-based .bin file, verify whether more than 72 hours have passed since it was generated.
-
If the 72-hour validity period has elapsed, restart the applicable activation process to obtain a valid response file.
-
-
Review the complete error message.
-
Check whether the "Requestor ID is invalid" message includes additional information about the cause.
-
Follow the appropriate corrective action based on the detailed error.
-
-
Contact Alteryx Support if the issue persists.
-
Submit a support case through the MyAlteryx Case Portal.
-
Include the complete error message, the licensing portal used, and the activation method.
-
A Customer Support Engineer can help identify the appropriate licensing workflow and next troubleshooting steps.
-
Important: Alteryx Support cannot use a .req file to generate a .bin activation response for keyless activation. This differs from the legacy Flexera request-file workflow. Do not assume that submitting a .req file to Support will result in a manually generated .bin file.