Welcome to the Alteryx Knowledge Base

Alteryx Designer Does Not Open on a Server Worker Node
user

Created/Edited - 9/18/2026 by Rajdeep Deb | Alteryx

Description

Alteryx Designer does not display its interface when launched on a Server Worker.

The process may appear briefly in Task Manager and then close without showing an error.

Issue

When Designer is launched:

 

  1. No application window is displayed.
  2. AlteryxGui.exe appears briefly in Task Manager and then terminates.
  3. Launching Designer as an administrator or directly from the installation directory produces the same result.
  4. Designer may continue to open normally on another Worker in the same environment.

 

The following events may appear in Windows Event Viewer:

 

Event 1026 – .NET Runtime

 

Application: AlteryxGui.exe

Framework Version: v4.0.30319

Description: The process was terminated due to an unhandled exception.

Exception Info: System.Runtime.InteropServices.SEHException

  image.png

 

Event 1000 – Application Error

 

Faulting application name: AlteryxGui.exe, version: 2025.2.1.24, time stamp: 0x691b715a

Faulting module name: KERNELBASE.dll, version: 10.0.20348.5020, time stamp: 0xe3683364

Exception code: 0xe06d7363

Faulting application path: E:\Alteryx\bin\AlteryxGui.exe

Faulting module path: C:\Windows\System32\KERNELBASE.dll

image.png

 

Environment

Alteryx Designer installed on a Windows Server Worker node.

On-premises, Multi-node Alteryx Server deployment.

Cause

The account launching Designer could not read the following node-level configuration file: C:\ProgramData\Alteryx\RuntimeSettings.xml


The file existed, but its permissions differed from those on the working Worker node.


A Process Monitor capture can confirm this condition by showing ACCESS DENIED when AlteryxGui.exe attempts to open RuntimeSettings.xml

Resolution
  1. Compare the access settings applied to the Alteryx configuration folder and "RuntimeSettings.xml" file on the affected Worker with those on a working Worker.
  2.  If any differences are found, align the affected Worker’s settings with the working node, following the organization’s standard change-control process.
  3. After the settings were aligned, Designer opened successfully. Back up the existing configuration before making changes, and do not copy or replace the "RuntimeSettings.xml" file between nodes.

 

Additional Information

If the issue persists after the steps above have been completed, please reach out to Alteryx Support for further investigation and assistance.

Was this article helpful?