Welcome to the Alteryx Knowledge Base
Created/Edited -
Users are unable to create or save a DCM (Data Connection Management) connection in Alteryx Gallery / Server.
The Gallery displays an error similar to:
Unknown error. AyxCryptoProviderException RequestID: 29feef8f3d384c6a93d1218d67ad62ce
When trying to create a DCM connection in the Gallery interface, user encounter an issue while attempting to save the connection.
Product: Alteryx Server (Gallery)
This issue is commonly caused by missing or incorrect Run As User permissions on the Alteryx Server environment.
Although the Gallery user may have sufficient Gallery permissions, the Alteryx Server service account must also have the required Windows permissions to:
- perform credential encryption,
- store DCM secrets,
- access crypto providers,
- and update credential storage securely.
If the service account cannot complete these operations, Server returns:
AyxCryptoProviderException
- Ensure that the required Server permissions are configured as outlined in the following Help documentation:
https://help.alteryx.com/20223/server/configure-required-run-user-permissions
- Additionally, verify that all affected users — specifically those running workflows using their own credentials — have Full Control permissions for the following folder on the Server machine:
%ProgramData%\Microsoft\Crypto\RSA\MachineKeys
This directory stores the encryption keys used by Alteryx to securely manage user credentials.
For more details on how credentials work, please refer to this article:
How Workflow Credentials Work on a Gallery