Welcome to the Alteryx Knowledge Base

Cross Tab Tool Fails to Dynamically Reset New Column Names
user

Created/Edited - 6/3/2026 by Ashfiya Khan | Alteryx

Description

The customer is developing a workflow in Cloud Native mode that utilizes the CrossTab tool.

 

While creating column names dynamically in the source dataset, the CrossTab tool fails to refresh the data dynamically in the existing workflow.

 

The expectation is that historical columns should be deleted and the latest columns should be added dynamically. In other words, column addition and removal should occur dynamically for the column names defined in the CrossTab configuration.

Issue

As per the current CrossTab functionality, when you use a CrossTab tool in your workflow for the first time, it picks the data based on your CREATE NEW COLUMN FROM field selection.

 

If that selected field receives new data in the future, the CrossTab tool creates a new column, which is the expected behavior.

 

However, if data is removed from the selected field values, that change is not applied to the generated column names.

 

As a result, the workflow retains a null-value column with an old column name that is no longer available in the source data.

Environment

Applies to:

  • Alteryx Analytics Cloud (AAC)
  • Designer Cloud
  • Cloud Native mode
  • CrossTab tool
Cause
Resolution

Workaround:

This is a limitation within Cloud native mode. The recommendation is to use one of the following alternatives:

  1. Run the workflow in Standard mode instead of Cloud Native mode.
  2. Utilize LiveQuery.
Was this article helpful?