Welcome to the Alteryx Knowledge Base
Created/Edited -
When creating an offline activation file for Alteryx Designer, uploading a request (REQ) file and selecting Create Activation File can return the following error:
"Failed to create activation file. Try again."
This can occur when a request file generated for license-key activation is submitted via the Alteryx One offline activation workflow rather than the Alteryx Licensing & Downloads workflow.
A network security control can also cause the activation request to fail. Follow the steps below to identify the licensing method used to create the REQ file and process it through the corresponding activation workflow.
When attempting to activate Alteryx Designer offline, the user successfully creates a request (REQ) file.
On an internet-connected computer, the user uploads the REQ file and selects Create Activation File.
The activation file is not generated and the following message is displayed:
Failed to create activation file. Try again.
No activation BIN file is downloaded.
Product: Alteryx Designer
Licensing:
- Alteryx One offline activation
- Unified/Legacy license-key offline activation
Designer Version:
- 2025.1 and later for Alteryx One file-based offline activation
- This issue has been confirmed with Designer 2025.2
Operating System:
- Microsoft Windows
Components:
- Designer Manage Licenses
- Alteryx One Download & Activate
- Alteryx Licensing & Downloads portal
- Offline REQ/BIN file activation
Before proceeding:
1. Generate the REQ file on the computer that needs to be licensed.
2. Have access to an internet-connected computer to process the REQ file.
3. Determine which licensing method applies:
- Alteryx One licensing, or
- License-key licensing.
4. For Alteryx One activation, the user must have access to the appropriate Alteryx One workspace and Designer entitlement.
5. For license-key activation, have the applicable license key available.
Do not reuse a REQ file created for a different computer or licensing method.
The most common cause is a mismatch between the licensing method used to create the REQ file and the activation workflow used to process it.
A REQ file generated using Unified/Legacy license-key activation must be processed through the Alteryx Licensing & Downloads license-key activation workflow.
An Alteryx One REQ file must be processed through Alteryx One > Download & Activate > Offline Activation.
Submitting a license-key REQ through the Alteryx One activation workflow can result in:
Failed to create activation file. Try again.
In environments that use web security or proxy inspection, the same generic message can also occur if the activation request is blocked. If browser diagnostics show an HTTP 403 Forbidden response, work with the organisation's IT/network team to review the blocked request.
First, determine how the REQ file was generated and use the corresponding activation method.
METHOD 1 — ALTERYX ONE OFFLINE ACTIVATION
Use this method when Designer is licensed through Alteryx One.
1. On the offline computer, open Alteryx Designer.
2. Go to:
Options > Manage Licenses > Activate New License > Activate Offline
3. Select the With Alteryx One tab.
4. Select Create Request File.
5. Save the REQ file and transfer it to a computer with internet access.
6. Sign in to Alteryx One.
7. Go to Download & Activate.
For older Designer versions such as Designer 2025.2, use the Older Designer Versions section where applicable.
8. Under Offline Activation, select Activate Offline.
9. Upload or drag and drop the REQ file.
10. Select Create Activation File.
11. Download the generated BIN file and transfer it to the offline computer.
12. In Designer, select Browse Activation File and select the BIN file.
13. Confirm that activation completes successfully.
Caption: Alteryx One offline activation workflow documented in Alteryx Help.
METHOD 2 — LICENSE-KEY OFFLINE ACTIVATION
Use this method when Designer is licensed with a Unified/Legacy license key.
1. Open Alteryx Designer.
2. Go to:
Options > Manage Licenses > Activate New License > Activate Offline
3. Create a new request (.req) file using the applicable license key.
4. Transfer the REQ file to an internet-connected computer.
5. Open the Alteryx Licensing & Downloads portal.
6. From the Home page, select Activate Offline License.
7. Select Next.
8. Upload the REQ file.
9. Select Next to process the request.
10. Download the generated BIN activation file.
11. Transfer the BIN file to the offline computer.
12. In Designer, open Manage Licenses and browse to the BIN file to complete activation.
Caption: License-key offline activation workflow documented in Alteryx Help.
IF THE CORRECT ACTIVATION METHOD STILL FAILS
1. Generate a new REQ file directly from the computer being licensed.
2. Confirm that the REQ is being uploaded through the corresponding activation workflow.
3. Reproduce the issue while capturing the browser network activity/HAR file.
4. Check the HTTP response generated when Create Activation File is selected.
5. If HTTP 403 Forbidden is returned, work with the organisation's IT/network team to determine whether a proxy or web-security service is blocking the activation request.
6. If the issue persists, contact Alteryx Support and provide:
- Designer version and build
- Screenshot of the error
- Newly generated REQ file
- The activation workflow being used
- Browser HAR file from the failed attempt
Additional Information
Alteryx Designer supports different offline activation workflows depending on the licensing method in use.
For Alteryx One licensing, file-based offline activation is supported starting with Designer 2025.1. The request (.req) file must be processed through the Alteryx One Download & Activate offline activation workflow.
For Unified or Legacy license-key licensing, the request (.req) file must be processed through the Alteryx Licensing & Downloads offline activation workflow.
If the correct activation workflow is being used and the error persists:
1. Generate a new .req file directly from the computer that requires activation.
2. Confirm that the request file is being uploaded through the corresponding licensing workflow.
3. Reproduce the issue while capturing a browser HAR file.
4. If the request returns HTTP 403 Forbidden, contact your network/security administrator to determine whether a proxy or web-security solution is blocking the activation request.
5. If the issue continues, contact Alteryx Support and provide:
- Alteryx Designer version and build
- Screenshot of the error
- Newly generated .req file
- Licensing method being used
- Browser HAR file from the failed activation attempt
Related Documentation
Alteryx Help — Activate License Offline with Alteryx One:
Alteryx Help — Activate License Offline with a License Key: