Welcome to the Alteryx Knowledge Base

Alteryx Designer, Alteryx Server Error: Can’t find the file: “[path\FileName]”. Make sure the file path is correct.
user

Created/Edited - 11/13/2026 by Lisa LePome | Alteryx

Description

The following error(s) can occur associated with a range of tools, but the most common are Input Data, Output Data, Directory, or Dynamic Input tool. Here are best practices to prevent a workflow from failing with these errors as well as some troubleshooting tips.

Can’t find the file: “[path\FileName]”. Make sure the file path is correct.
Invalid directory “[path\FileName]”: The system cannot find the file path specified.


In versions prior to 2021.1.4, you will see the shorter error message:

File not found "[path\FileName]"
Environment
  • Alteryx Designer or Alteryx Server
    • All Versions
Cause

Alteryx cannot access one or more files that the workflow requires.
 

image.png

Resolution
  1. Verify that the file is specified correctly in the tool.
    1. Check that the file is in the expected location.
    2. Verify that the file name has been specified accurately, including file type extension.

  2. Make sure that Alteryx is configured to have access to the location. If running on Server, note that each Server Worker node will need to be able access that location.
    1. In the above example image, the path to the desired workflow includes a mapped drive letter (Z:)  This is not the best way to designate a path when writing a workflow.  Instead, best practice is to use a UNC path.  A UNC path has a format that gives the hostname as well as the directory structure in which the desired file is located, for example: 
      \\HostnameDOTdomainDOTcom\MainDirectoryName\SubDirectories\Filename.csv
    1. If you have used a mapped drive letter instead of a UNC path, the workflow will probably run correctly from your desktop Designer because you are running from your own account, but this is not the best practice because if you ever share your workflow with a colleague or schedule it to run automatically or publish it to Server, you'll find that running the workflow in the new environment causes it to fail. 

image.png
 
    1. You can use the All UNC button to change the paths to UNC paths, and if you desire, you can also test the location to confirm.   Click OK to make the change in the workflow.

 

image.png

 

    1. In the scenarios noted above, the colleague or the AlteryxService must have permission to access network shared resources, even with the UNC path.  There is more information on configuring Desktop Automation or Server to grant appropriate permissions in other articles.

  1. The path length cannot be longer than 260 characters.
Additional Information
Was this article helpful?