Welcome to the Alteryx Knowledge Base

Error: Root element is missing. (xxxx-xxxx-xxxx-xxxx-xxxx-xxxx-xxxx-xxxx) Root element is missing. Contact your license administrator for help with licensing.
user

Created/Edited - 10/10/2026 by Nora Tobon | Alteryx

Issue

The following error appears when attempting to activate Designer:

 

Root element is missing. (xxxx-xxxx-xxxx-xxxx-xxxx-xxxx-xxxx-xxxx)
Root element is missing. Contact your license administrator for help with licensing.

 

Environment

Alteryx Desktop Designer and Alteryx One Licensing

Cause

Corrupt SRC folders

Resolution

Delete SRC folders:

1. Close Alteryx Designer completely.
2. Navigate to the following folders on the affected machine:
C:\ProgramData\SRC 
C:\Users\<your username>\AppData\Roaming\SRC
3. Delete the contents of these folders, if present.
4. Reopen Alteryx Designer.
5. Attempt to activate the license again.

Additional Information
Was this article helpful?