Welcome to the Alteryx Knowledge Base

Error: "This connection is not allowed for SDK" When Using Auto Insights Uploader v1.4
user

Created/Edited - 12/6/2024 by Ralph Kong | Alteryx

Summary
When using Auto Insights uploader v1.4 for Designer 2021.4, DCM needs to be enabled.
And SDK Access Mode must be Allow instead of AllowAll
Environment

Error: "This connection is not allowed for SDK"


Environment Details


When using Auto Insights uploader v1.4 for Designer 2021.4, Data Connection Manager (DCM) needs to be enabled. If "SDK Access Mode" option is set to "AllowAll", then the “connect” button in the Connections of DCM is disabled. The following error will be shown:
This connection is not allowed for SDK






 
  • Alteryx Designer
    • version 2021.4
  • Alteryx Auto Insights Loader 
    • version 1.4
Cause

Cause


When the "SDK Access Mode" for DCM is set to “Allow All”, the “Connect” button in DCM is disabled, preventing you from linking your DCM credentials to Auto Insights uploader
Resolution

Resolution

 

In Designer, Options-->User Settings-->DCM, set SDK Access Mode to Allow. Restart Designer and re-create Auto Insights connection.  