Welcome to the Alteryx Knowledge Base

[Designer] - LLM connection returns 500 Internal Server Error
user

Created/Edited - 5/20/2026 by Marni Monika | Alteryx

Description

This issue can occur when a user creates an LLM connection in Alteryx One and uses that connection with GenAI tools in Designer. When the workflow runs, Designer returns a 500 Internal Server Error.

Issue

A user creates an LLM connection in Alteryx One and uses that connection to configure GenAI tools in Designer. When the workflow runs, the following error appears:

 

Error occurred in LLM response generation: 500 Server Error: Internal Server Error for url: https://us1.alteryxcloud.com/aims/v1/generatedContent

 

 

Environment

Designer 2025.1 and later
Alteryx One
GenAI tools using an LLM connection

Cause

The required Alteryx One control plane IP addresses are not allowlisted in the user network.

Resolution

Allowlist the required control plane IP addresses for Alteryx One.

 

Use the IP address ranges listed in the following documentation:

https://help.alteryx.com/aac/en/platform/getting-started-with-alteryx-one.html#allowlist-the-ip-address-range-of-the-alteryx-service-4694173

 

In some environments, IT teams may also need to allowlist the required Alteryx domains and network ports.

 

Domains
whitelist.alteryx.com
*.alteryx.com
*.alteryxcloud.com

 

Region-specific URLs
https://us1.alteryxcloud.com/
https://eu1.alteryxcloud.com/
https://au1.alteryxcloud.com/

 

Ports
80
443

 

After the required IP addresses, domains, and ports are allowlisted, run the workflow again.

Additional Information

Work with IT or network team to confirm that all required Alteryx One endpoints are allowlisted. If the issue continues after allowlisting, review the network rules and confirm that traffic to the correct regional Alteryx One URL is allowed.