Welcome to the Alteryx Knowledge Base

Prescriptive tools are Missing after Installing AIS and Predictive tools
user

Created/Edited - 8/7/2026 by Ashfiya Khan | Alteryx

Description

Prescriptive tools are not available after installing Alteryx Intelligent Suite (AIS) and Predictive Tools. This issue can occur when the installed versions or installation types do not match the version and installation type of Alteryx Designer.

Issue

Prescriptive tools are missing after installing Alteryx Intelligent Suite (AIS) and Predictive Tools.

Environment
  • Alteryx One
  • Alteryx Designer
  • Alteryx Intelligent Suite (AIS)
Prerequisites
  • Verify the version of Alteryx Designer installed.
  • Verify whether Designer is installed as an admin or non-admin installation.
Cause

The installed versions of AIS and Predictive Tools do not match the Designer version or Designer installation type. 

Resolution
  1. Ensure the versions of AIS and Predictive Tools installed match your Designer version.
    • If you use the admin version of Designer, install the admin version of the Predictive Tools.
    • If you use the non-admin version of Designer, install the non-admin version of the Predictive Tools.

Note 1:
If you have both admin and non-admin versions of Designer installed, you can confirm which version is being used by launching Designer through the Alteryx One app and then in Task Manager:

  1. Open Task Manager.
  2. Select the Details tab.
  3. Right-click AlteryxGUI.exe and select Properties.
  4. Check the location of the executable (.exe):
    • If the location is in your user folder, it is a non-admin installation, and you need the non-admin versions of AIS and Predictive Tools.
    • Otherwise, install the corresponding admin versions.

Note 2:
If the tools were removed after an update, this is currently expected behavior. The Alteryx One app installs only the base Designer application and does not install add-ons or extras. Alteryx Intelligence Suite and Predictive Tools remain separate installations and are removed when previous versions of Designer are uninstalled.

 

Note 3:

  • Sometimes, Alteryx Intelligence Suite (AIS) prompts to reinstall in version 26.1+ even though it is already installed.
    • A common cause is again an install-type mismatch between the Alteryx One App and Alteryx Intelligence Suite. For example, if the app was installed as per-user but the Alteryx Intelligence Suite was installed as per-machine, the Designer can treat the add-on as missing.
    • Reinstall so both products use the same installation type.
Additional Information
Was this article helpful?