Welcome to the Alteryx Knowledge Base

Salesforce tools: Using Salesforce Credentials (non-DCM) does not obtain new access token
user

Created/Edited - 9/14/2025 by Clara Boo | Alteryx

Issue

Using the Salesforce credentials authentication method without using the Data Connection Manager (DCM) causes the workflow to fail and throws the following errors:

 

The requested resource doesn't exist
'list' object has no attribute 'get'

 

 

NOTE: The above errors also apply to the Sign in via Internet Browser authentication option.

 

Environment
  • Alteryx Designer
    • Version: All
  • Salesforce Tools
    • Version >= 5.1.0
  • Authentication Method 
    • Sign in via Internet Browser 
    • Salesforce Credentials

 

Prerequisites
  • Data Connection Manager (DCM) is NOT used.

 

Cause

The error occurs when the access token has become invalid due to a session timeout, and a new token is not obtained. This issue only affects non-DCM use of any authentication methods (Sign in via Internet Browser or Salesforce Credentials). A defect (GCSE-3599/TPM-4866) has been logged to address this.

 

NOTE: The session timeout can be from 15 minutes to 2 hours or more, depending on the setting in Salesforce.

 

Resolution

Please consider one of the following solutions, if applicable.

 

Solution A: Reconnect in the Salesforce tool

The error can be addressed by reconnecting to Salesforce from the tool configuration. 

Steps:

  1. Click the X to disconnect from the tool.

 

  1. Click the Connect button to reconnect to Salesforce.

 

NOTE: You will need to repeat the above steps whenever you encounter the error.

 

Solution B: Use DCM to configure the connection

Reconfigure the tool to use the Salesforce Credentials authentication method in DCM.

 

If you are using the Sign in via Internet Browser option,  please use the Built-in App option in DCM.

 

 

 

Solution C: Use another authentication method

If applicable, consider the use of the following method:

  • Custom App (Only available in DCM)

 

 

 

NOTE: The use of DCM is mandatory if you are using the connector on Alteryx Server.

Was this article helpful?