Welcome to the Alteryx Knowledge Base

Server automation tracking report fails with “Attempt to read past the end of a blob”
user

Created/Edited - 9/23/2026 by Rajdeep Deb | Alteryx

Description

The Server Automation Tracking Report workflow fails with "Attempt to read past the end of a blob" when processing larger date ranges due to the MongoDB ODBC Binary Size setting.

Issue

The Server Automation Tracking Report workflow fails with the error “Internal Error: Attempt to read past the end of a blob” when running the report for larger date ranges.

 

The workflow may still connect to MongoDB and generate a PDF, but the run completes with an error.

 

 

 

 

Environment

Alteryx Server

Server Automation Tracking Report

MongoDB ODBC Driver

Cause

This can occur when the MongoDB ODBC Driver Binary Size setting is not large enough to handle the data returned by the Server Automation Tracking Report for larger date ranges.

Resolution

Update the Binary Size setting in the MongoDB ODBC DSNs used by the Service and Gallery connections to: 2147483647


After updating the Binary Size value, rerun the Server Automation Tracking Report.

Additional Information
Was this article helpful?