Welcome to the Alteryx Knowledge Base

SharePoint Tools: Errors that may occur when using DCM Connection Handling
user

Created/Edited - 10/6/2025 by Clara Boo | Alteryx

Issue

SharePoint tools (Input/Output) do not work for every authentication combination in DCM Connection Handling. 

 

Below is an example of a failed job after using DCM Connection Handling:

 

 

Configuration Example:

In DCM connection handling (Admin > DCM Connection Handling), the connection ID ( b46bf927-9c26-449f-99ab-ac8e4fd798b7) has been configured to use another DCM connection as shown below:

 

 

The following table shows the authentication method that works and the errors for those that do not work when DCM Connection Handling is used:

 

Source Connection to Target ConnectionVersion 2.7.1 (Working?)Version 2.7.2 (Working?)Version 2.7.3 (Working?)Error Messages

Source: Service Principal

Target: Service Principal 

NoYesYes

Version 2.7.1 fails with the following error:

<class 'AttributeError'>: 'NoneType' object has no attribute 'strip'

Source: Built-in App

Target: Service Principal 

NoNoNo

Version 2.7.1 fails with the following error:

Failed to authenticate

 

Versions 2.7.2 and 2.7.3 fail with the following errors:

 

  • User must be logged in.
  • <class 'TypeError'>: 'NoneType' object does not support item assignment

Source: Custom App

Target: Service Principal 

NoNoNo

Version 2.7.1 fails with the following error:

Failed to authenticate

 

Versions 2.7.2 and 2.7.3 fail with the following errors:

 

  • User must be logged in.
  • <class 'TypeError'>: 'NoneType' object does not support item assignment

Source: Service Principal

Target: Built-in App

NoNoNo

All versions show the following error:

<class 'AttributeError'>: 'NoneType' object has no attribute 'get'

Source: Service Principal

Target: Custom App

NoNoNo

All versions show the following error:

Failed to authenticate.

Source: Built-in App

Target: Built-in App

YesYesYes

 

Source: Custom App

Target: Custom App

YesYesYes

 

Source: Built-in App

Target: Custom App

NoNoNo

All versions show the following error:

Failed to authenticate.

Source: Custom App

Target: Built-in App

NoNoNo

All versions show the following error:

<class 'AttributeError'>: 'NoneType' object has no attribute 'get'

 

IMPORTANT:

Target that uses either the built-in app or the custom app needs the DCM connection to be used once in the SharePoint tool in Designer. You do NOT need to save the workflow. Once the connection is established, you need to synchronise it to the Gallery to avoid the errors below.

 

Version 2.7.1 (Built-in app as the target connection):

 

Failed to authenticate

 

Version 2.7.1 (Custom app as the target connection):

 

<class 'AttributeError'>: 'NoneType' object has no attribute 'strip'

 

Versions 2.7.2 and 2.7.3 (Built-in app or Custom app as the target connection):

 

User must be logged in.
<class 'TypeError'>: 'NoneType' object does not support item assignment

 

 

Environment
  • Alteryx Designer/Server
    • Version: All
  • SharePoint Tools
    • Version >= 2.7.1
  • Authentication Method:
    • Service Principal
    • Custom App
    • Built-in App

 

Cause

A defect (GCSE-3562/TPM-4822) has been logged to address these errors.

 

Resolution

Solution A: Upgrade SharePoint Tool Version

 

The error for the different authentication method combinations in the DCM Connection Handling has been addressed in SharePoint version 2.7.4. Please download this release from Alteryx Marketplace.

 

Solution B: For SharePoint Tool Version < 2.7.4

 

There is no suitable workaround for the failed combinations as mentioned in the Issue section. Only the same authentication method used in both the Source and the Target in DCM Connection Handling works for now. The Service Principal authentication method used in both the Source and the Target does not work in version 2.7.1. If you are using this authentication method in both the Source and the Target, please use version 2.7.2 or above.

 

Was this article helpful?