Description

Users may be unable to access the Alteryx One App because the application continuously redirects them back to the sign-in page after successful authentication. This behavior prevents users from completing the sign-in process and accessing the application.

Issue

After successfully authenticating, the Alteryx One App redirects the user back to the sign-in page, resulting in an endless authentication loop.

(1) Prompted to Sign In

(2) Authentication to AAC is successful

(3) Still prompted to Sign In

 

Environment
  • Alteryx One App
    • 2026.1+

 

Cause

Alteryx One App's TLS is failing and needs to use the Windows OS native TLS implementation

Resolution

Direct Alteryx One App to use Windows OS native TLS implementation by editing the settings file

  • %AppData%\Alteryx\alteryx-one-settings.json

For a Server machine, a SECOND copy of the file must ALSO be edited

  • %ProgramFiles%\Alteryx\AlteryxOne\alteryx-one-settings.json 

This file contains a location and baseURL specific to your region (US/EU/AU).  You will add to this file:

  • a comma at the end of the baseUrl line
  • the line "useNativeTls": true without a comma at the end

For example, for a US Region file, the following is added:

{
  "location":  "US",
  "baseUrl": "us1.alteryxcloud.com",   
  "useNativeTls": true
}

Note:  Make a copy of the file before editing.

Restart Alteryx One App after updating the settings file and Sign In again.

-------------------------------------------------------------------------------------------------