Welcome to the Alteryx Knowledge Base

Error: "serverUrl" is displayed when using Tableau tools with DCM Connection Handling
user

Created/Edited - 9/18/2025 by Clara Boo | Alteryx

Issue

Tableau tools return the following error if DCM connection handling is used:

 

'serverUrl'

 

 

NOTE:  The above workflow uses the DCM connection (8c830057-c09c-4343-aa6f-6152c7bd0917) that has been configured to use DCM connection handling.

 

Configuration Example;

 

In DCM connection handling (Admin > DCM Connection Handling), the connection ID (8c830057-c09c-4343-aa6f-6152c7bd0917) has been configured to use another DCM connection as shown below:

 

 

 

NOTE: The Admin console requires the role of Curator.

 

Another usage that can cause this error is when the DCM connection is shared with other users for collaboration in Home > DCM Data Sources, and the users use it in Designer.

 

 

 

 

Environment
  • Alteryx Server
    • Version >= 2024.1
  • Tableau Tools
    • Version: 1.5.3
Cause

The error occurs if the DCM connection has not been used once after creation.

A defect (GCSE-3476/TPM-4732) has been logged to address the error.

 

Resolution

Solution A: Upgrade Tableau tool version

 

This issue has been addressed in Tableau tool version 1.5.4.  In this version, you do NOT need to perform a connection on the DCM connection used in the Target Connection field of the DCM Connection Handling or shared with other users.  Please upgrade to this release.

 

 

Solution B: Tableau tool version < 1.5.4

 

To address the error in the Tableau tool version < 1.5.4, please ensure that the DCM connection that is used in the Target Connection field of the DCM Connection Handling or shared with other users has been used/connected once in a workflow.

The owner of the DCM connection has to perform the following steps:

  1. Open Designer and add a Tableau Input tool or Tableau Output tool to a new workflow. The tool to use depends on the DCM connection you have configured for (input or output).

  2. Configure the tool to use the DCM connection created for use in the DCM Connection Handling or shared with other users.
  3. Once connected, go to Files > Manage Connections to synchronise this change to the Gallery.
  4. For the DCM connection handling issue, run the workflow in the Gallery, and it should work now.  If this DCM connection is shared for collaboration, the user(s) will have to perform the synchronisation in Designer.

 

NOTE:

  • You will need to synchronise the DCM connections in Designer if the DCM connection is added in the Gallery first in order to use the DCM connection in Designer.
  • You do NOT need to keep or save the above workflow; it is just used to connect to the created DCM connection once.
  • Please refer to this article if you encounter the "Failed to siginin to Tableau" error after this.

 

 

 