Welcome to the Alteryx Knowledge Base
Created/Edited -
Using DCM Connection Handling for Tableau Tools returns the following error:
Failed to signin to Tableau.
NOTE: The above workflow uses the DCM connection (d338134c-2a7e-4e1c-810d-39d767b54a83) that has been configured to use DCM connection handling.
Configuration Example;
In DCM connection handling (Admin > DCM Connection Handling), the connection ID (d338134c-2a7e-4e1c-810d-39d767b54a83) has been configured to use another DCM connection as shown below:
NOTE: The Admin console requires the role of Curator.
- Alteryx Server
- Version >= 2024.1
- Tableau Tools
- Version: 1.5.3
- Authentication Method
- Personal Access Token (PAT)
- Username/password
The error happens because an incorrect token name for PAT was used. For the username/password authentication, the username was not correct. A defect (GCSE-3498/TPM-4751) has been logged to address this.
Solution A: Upgrade Tableau tool version
This issue has been addressed in Tableau tool version 1.5.4. Please upgrade to this release.
Solution B: Tableau tool version < 1.5.4
Please consider the following workaround if you are unable to upgrade to the tool version 1.5.4 or above.
For the Personal Access Token (PAT) authentication method
- Create a new token in both environments (Source and Target) with the same token name. For example: TestJuly2025
- Modify the DCM connection in both the source and target to use the token name and the generated secret.
NOTE: If both source and target environments are the same environment and you are using a single account for all users in Source, you must create an additional account with the same token name to be used in Target. In summary, the source and target must use different accounts with the same token name.
For Username/Password authentication method
Please use PAT authentication method with the above workaround. If, however, the Tableau server used in both the source and target connections is different, use the same user account for both environments.