In-DB Tool Error: Selected connection is not available
user

Created/Edited - 1/5/2026 by Michael Phipps | Alteryx

Description

Error publishing or running workflow from Gallery that uses In-DB Tool with DCM connection:

 

'Error: Selected connection is not available'

 

Selected Connection is not available. Set one up to use the tool.
Environment
  • Alteryx Server
  • Alteryx Designer
  • In-DB Tools
  • DCM
Prerequisites

In-DB tool used in workflow that uses DCM connection details and is run from Gallery

Cause
  • This error is seen when the DCM connectionId does not exist at both machines.
  • Is it also possible the user/admin mistakenly manually setup the DCM connection on Designer and then again using the same name made it in the UI; making a DCM connection name the same but the connection ID (unique identifier) is actually different.
Resolution

This can be resolved two ways:

a. Create a SYSTEM In-DB connection Name in Server's Designer

This can be created in Server's Designer using the same naming convention and selecting the sync'ed DCM connections, as shown in the screenshot.

 

Learn more about How to setup In-DB connection from Server's Designer to allow connection to be found.

 

 

 

 

kcs.png

 

 

b. Copy the In-DB connection details from the User's Designer UserConnections.XML to the Server's SystemConnections.XML

This is programmed manually. 

Please note the InDBConnection Name="00704503TEST" used in this example:

 

kcs2.png

 

Additional Information