After installing Alteryx Predictive/R tools, the settings files below do not contain any value in some of the XML elements.
-
- <INSTALLED_PATH>\Settings\AdditionalPlugins\Rplugin.xml
- <INSTALLED_PATH>\Alteryx\Settings\RPluginSettings.xml
- <INSTALLED_PATH>\Alteryx\Settings\AddOnData\Samples\R-<VERSION>_Samples.xml
- <INSTALLED_PATH>\Alteryx\Settings\AddOnData\Macros\R-<VERSION>_Macros.xml
Examples:
- Alteryx Designer/Server
- Version >= 2022.3
- Alteryx Predictive Tools/R tool
The security/defender software is running in the background, scanning all the files that are added by the installation process while it is still ongoing. One of the components in the installation exited with an access violation (0xc0000005) error as seen in the Windows Event Viewer > Windows Logs > Application below.
In this particular example, it was caused by SentinelOne:
This component happens to be the one that performs the Settings file updates. Because it has failed, the Settings files are not updated with the appropriate values, causing the following issue:
The solution in the above article can be applied to address the missing values, but the same issue may still occur in future installations; therefore, it is best to address the cause of the missing values.
NOTE: The Predictive/R tools installation still reflects as completed successfully, as the main component has been installed without any issues.
To prevent the issue from recurring in future installations, please work with your IT team to disable or exclude any policy on the security/defender software that performs file scanning of the installed files during installation.
For example, if you are using SentinelOne, disable or bypass the real-time scanning on the MSI (MsiExec.exe) or add a policy to exclude real-time scanning on the Alteryx installer and its sub-processes in the SentinelOne Management Console.. Please work with your IT team to ensure that the applied policy works well.